BG CURAFDB16DPA Bidirectional AFDD RCBO: 16A B Curve, 30mA Type A, 6kA, 1P+N (Double Pole) Single Module Arc Fault Protection.

The BG CURAFDB16DPA combines an Arc Fault Detection Device and a 16A RCBO in one 17.85mm module. It gives arc fault, earth leakage, overload and short-circuit protection from a single DIN rail position. It switches both live and neutral as standard and is bidirectional, so you can wire it to suit the board layout.

Arc Fault Detection for Radial Circuits

The 16A rating and B Curve characteristic make the CURAFDB16DPA well suited to radial circuits and power circuits running low-power appliances in domestic and light commercial installations. It detects series arcing in damaged cable, parallel arcing between conductors, and parallel arcing between live and earth, all of which a standard MCB, RCBO or RCD cannot see. Faults are cut off before they can develop into an electrical fire.

Protection covers the full circuit, including spurs and connected leads. That makes it a strong choice for bedrooms, HMOs, rental properties and any installation where fire risk needs to be kept to a minimum.

Reliable Protection in Tough Conditions

The 30mA Type A residual current protection detects pulsed DC above 6mA, so earth leakage protection stays dependable on circuits feeding modern electronic appliances. The 6kA breaking capacity provides robust short-circuit protection.

Pollution Degree 3 testing and a −25°C to +40°C operating range keep the device reliable in enclosures exposed to condensation or changing temperatures, such as garages, workshops and external boards.

Quick Retrofit & BS 7671 Compliance

The single module format fits the BG range of consumer units and enclosures and retrofits easily into existing boards. You can upgrade a circuit to AFDD protection without replacing the consumer unit. Double pole switched neutral disconnection fully isolates the circuit for safer testing and fault finding.

The device complies with BS 7671 Amendment 4 and is built to IEC/EN 61009-1 and IEC/EN 62606, with CE and UKCA marking. An integral test button allows routine testing in line with the IET Wiring Regulations, which supports your certification and handover paperwork.

Key Features of the BG Bidirectional AFDD RCBO 16A B Curve 30mA CURAFDB16DPA Include:

  • Combined AFDD & RCBO Protection In A Single Module To Save Board Space
  • Detects Series & Parallel Arc Faults To Help Prevent Electrical Fires
  • Suits Radial & Low-Power Domestic Or Light Commercial Circuits
  • Protects Circuits, Spurs & Connected Leads
  • Bidirectional For Flexible Top Or Bottom Feed Wiring
  • 1P+N (Double Pole) Switched Neutral Disconnection For Full Circuit Isolation
  • Fits BG Consumer Units & Enclosures And Retrofits Easily Into Existing Installations
  • Integral Test Button For Routine Testing
  • 16A Rated Current
  • B Curve Trip Characteristic
  • 30mA Type A RCD With >6mA Pulsed DC Detection
  • 6kA Breaking Capacity
  • 230V AC 50Hz Rated Operational Voltage
  • Pollution Degree 3 Tested
  • Operating Temperature: -25°C To +40°C
  • Electrical Endurance: 4,000 Cycles; Mechanical Endurance: 20,000 Operations
  • Height: 117.7mm
  • Width: 17.85mm
  • Depth: 75.3mm
  • BS 7671 Amendment 4 Compliant
  • Manufactured To IEC/EN 61009-1 & IEC/EN 62606, CE & UKCA Marked

View all BG Electrical Products

View BG Consumer Units

If you just need some help, would like to take advantage of our Price Promise or perhaps have a large order to place give our team of professionals a call on 0203 994 5470, drop us an email at sales@electricpoint.com or use our Contact Form.

Model Number: CURAFDB16DPA
Brand: BG (British General)
Range: BG Circuit Protection
Product Type: Bidirectional AFDD RCBO
Rated Current: 16A
Curve: B
Breaking Capacity: 6kA
Bidirectional: Yes
Number of Poles: 2P
Type of Pole: 1P+N (Double Pole), Switched Neutral
Module Width: 1 Module
Fixing Mode: DIN Rail
Rated Residual Operating Current: 30mA
RCD Type: Type A (>6mA Pulsed DC Detection)
Rated Operational Voltage (Ue): 230V
Max Operating Voltage: 264V
Rated Insulation Voltage: 400V
Rated Impulse Withstand Voltage: 4kV
Frequency: 50Hz
Type of Supply Voltage: AC
Pollution Degree: 3
Operating Temperature: -25°C to +40°C
Electrical Endurance: 4,000 Cycles
Mechanical Endurance: 20,000 Operations
Terminal Type: Screw Terminal, Pozidriv PZ2
Max Cable Capacity: 16mm² (L2), 10mm² (L1/N1)
Height: 117.7mm
Width: 17.85mm
Depth: 75.3mm
Standards: IEC/EN 61009-1, IEC/EN 62606
Compliance: BS 7671 Amendment 4 Compliant, CE & UKCA Marked