Hager RCD 100A Type A 30mA 2 Pole 2 Module CDA285U

Product Code CDA285U

reviews

Available for Delivery only, change to Fast Delivery Service

£41.91

exc VAT

£50.29 : inc VAT

£50.29

inc VAT

£41.91 : exc VAT

  • BULK SAVINGS!
  • QTY Unit Price
  • 1-2 £41.91 £50.29
  • 3+ £41.63 £49.95

Qty:

Hager CD285U: 100A 30mA 2 Pole RCCB Type A, a DIN rail mounted residual current circuit breaker for earth fault protection on line and neutral circuits.

Safety & Reliability

This Hager RCCB opens the circuit automatically the moment it detects an earth fault between line and earth, or neutral and earth, cutting power before a fault becomes a hazard. The trip-free mechanism means the switch cannot be held closed against a fault condition, so protection stays effective even under manual interference. Built to BS EN 61008 and IEC1008, it gives contractors a compliant, tested device for consumer units and distribution boards where reliable residual circuit current breaker performance is required.

Clear Status Indication

A rectangular flag indicator shows switch position at a glance: red for closed, green for open, removing any guesswork during inspection or fault-finding. A separate yellow flag confirms when the device has tripped, so engineers can quickly identify which RCCB has operated in a board full of similar units. This visual feedback speeds up diagnosis on site and reduces callback time when isolating faults.

Installation & Compliance

Terminal capacities of 50mm² rigid and 35mm² flexible conductor at this 100A rating make the CD285U straightforward to wire into higher-current distribution circuits, while the 2-module DIN rail footprint keeps panel space to a minimum. The device can be padlocked on or off using a Hager MZN175 accessory, giving installers a simple way to lock out circuits during maintenance. As a Hager Ltd manufactured product with IP20 ingress protection and a 500V rated insulation voltage, it's built for standard indoor distribution board use.

Key Features of the Hager CD285U Residual Current Circuit Breaker Include:

  • Automatically Disconnects Supply On Earth Fault Between Line/Neutral And Earth
  • Trip-Free Mechanism Prevents Override During A Fault Condition
  • Red/Green Flag Indicator Shows Closed/Open Switch Position At A Glance
  • Yellow Flag Indicator Confirms When The Device Has Tripped
  • Lockable On Or Off Using A Hager MZN175 Padlock Accessory
  • Suitable As A Residual Current Circuit Breaker (RCCB) For Domestic And Commercial Distribution Boards
  • Rated Current: 100A
  • Rated Residual Operating Current: 30mA
  • Number Of Poles: 2
  • Leakage Current Type: Type A
  • Rated Voltage: 230V, 50Hz
  • Rated Insulation Voltage (Ui): 500V
  • Rated Impulse Withstand Voltage (Uimp): 4kV
  • Terminal Capacity (100A Rating): Rigid 50mm², Flexible 35mm²
  • Mounting Method: DIN Rail, Width 2 Modules
  • Degree Of Protection: IP20
  • Ambient Operating Temperature: -25°C And Above
  • Compliant With BS EN 61008 & IEC1008
If you need some help, would like to take advantage of our Price Promise or have a large order to place, give our team of professionals a call on 0203 994 5470, drop us an email at sales@electricpoint.com or use our Contact Form.

Model Number: CD285U
Brand: Hager
Manufacturer: Hager Ltd
Product Type: Residual Current Circuit Breaker (RCCB)
Rated Current: 100A
Rated Residual Operating Current: 30mA
Number Of Poles: 2
Leakage Current Type: Type A
Rated Voltage: 230V
Frequency: 50Hz
Rated Insulation Voltage (Ui): 500V
Rated Impulse Withstand Voltage (Uimp): 4kV
Short-Circuit Breaking Capacity (Icw): 6kA
Surge Current Capacity: 3kA
Pollution Degree: 2
Mounting Method: DIN Rail
Width: 2 Modular Spacings
Recess Depth: 70mm
Degree Of Protection (IP Rating): IP20
Connectable Conductor Cross Section (Solid-Core, Min): 1mm²
Connectable Conductor Cross Section (Multi-Wired, Min): 1mm²
Terminal Capacity (100A Rating): Rigid 50mm², Flexible 35mm²
Ambient Operating Temperature: -25°C
Compliance: BS EN 61008, IEC1008