Hager RCD 100A Type AS 100mA Double Pole CN584U

Product Code CNA584U

reviews

Available for Delivery only, change to Fast Delivery Service

£87.49

exc VAT

£104.99 : inc VAT

£104.99

inc VAT

£87.49 : exc VAT

  • BULK SAVINGS!
  • QTY Unit Price
  • 1-2 £87.49 £104.99
  • 3+ £86.58 £103.90

Qty:

Hager CNA584U: 100A 100mA Type A S RCCB (1 Pole+Neutral) for TT earthing systems.

Safety & Reliable Earth Fault Protection

This residual current circuit breaker (RCCB) uses a trip-free mechanism, so the contacts cannot be forced or held closed during a fault. Type A sensitivity picks up both standard AC residual currents and pulsating DC currents, giving broader protection than a basic AC-type device on mixed electrical loads.

Built for TT Earthing Systems

On TT installations, where there's no dependable low-resistance path back to the source earth, a residual circuit current breaker like this one becomes the primary line of defence against earth faults. The S rating adds a short time delay, so this RCCB holds back long enough for downstream RCDs to trip first, keeping supply running to unaffected circuits while still isolating the fault.

Installation & Compliance

The unit can be padlocked in either the on or off position using the optional Hager MZN175 accessory, useful for isolation during maintenance or testing. It's built to BS EN 61008 and IEC1008 standards by Hager Ltd. Note this is a dedicated RCCB for residual current protection only; it doesn't cover arc faults in the way a Hager AFDD does, so specify the two device types separately where both protections are required.

Key Features of the Hager CNA584U Include:

  • Protects Against Earth Leakage Current On TT Earthing Systems Lacking A Low-Resistance Earth Path
  • Type A Sensitivity Detects Both AC And Pulsating DC Residual Currents
  • Time-Delayed S Rating Allows Downstream RCDs To Trip First, Maintaining Supply Continuity
  • Trip-Free Mechanism Prevents Contacts Being Held Closed During A Fault
  • Padlockable On Or Off Using Optional Hager MZN175 Accessory
  • Pole Configuration: 1 Pole+Neutral
  • Rated Current: 100A
  • Rated Residual Operating Current: 100mA
  • Sinusoidal Time-Delayed Device (Type A S)
  • Compliant With BS EN 61008 & IEC1008 Standards
  • Manufactured By Hager Ltd

If you need some help, would like to take advantage of our Price Promise or have a large order to place, give our team of professionals a call on 0203 994 5470, drop us an email at sales@electricpoint.com or use our Contact Form.

Model Number: CNA584U
Brand: Hager
Manufacturer: Hager Ltd
Product Type: Residual Current Circuit Breaker (RCCB)
Pole Configuration: 1 Pole+Neutral
Rated Current: 100A
Rated Residual Operating Current: 100mA
Type: Type A S (Sinusoidal, Time-Delayed)
Suitable Earthing System: TT
Mechanism: Trip-Free
Padlockable: Yes (With MZN175 Accessory)
Compliance: BS EN 61008, IEC1008
Lifecycle Status: Active