Hager CDA240U: 40A 30mA 2 Pole RCCB Type A residual current circuit breaker (RCCB) for DIN rail distribution boards, manufactured by Hager Ltd.

Safety & Reliability

This residual current circuit breaker rccb trips automatically when it detects an earth fault between line and earth, or neutral and earth, cutting the circuit before a fault becomes dangerous. Type A leakage current detection covers both AC and pulsating DC fault currents, giving broader protection than a standard Type AC device on mixed installations.

A trip-free mechanism prevents the contacts from being held closed during a fault, and the unit can be padlocked on or off using an MZN175 accessory for safe isolation during maintenance and testing.

Clear Fault Indication

A rectangular flag indicator shows contact position at a glance: red for closed, green for open. When the device trips on a fault, the flag switches to yellow, letting engineers identify a tripped rccb without opening the enclosure or running a full board test.

Installation & Compliance

DIN rail mounting and a 2-module width keep panel layouts compact, while terminals accept up to 25mm² rigid or 16mm² flexible conductors for straightforward first-fix and testing. The unit is built to BS EN 61008 and IEC1008, making it a straightforward specification choice for compliant residual circuit current breaker protection on commercial and domestic boards.

Where a board also needs arc fault detection, this RCCB pairs with a Hager AFDD device so earth leakage and arcing fault risks are both covered within the same distribution board.

Key Features of the Hager CDA240U Include:

  • Automatically Disconnects The Circuit On An Earth Fault Between Line And Earth, Or Neutral And Earth
  • Type A Leakage Detection Covers Both AC And Pulsating DC Fault Currents
  • Trip-Free Mechanism Prevents Contacts Being Held Closed During A Fault
  • Padlockable On Or Off Using An MZN175 Accessory For Safe Isolation
  • Rectangular Flag Indicator: Red = Closed, Green = Open, Yellow = Tripped
  • Rated Current: 40A
  • Rated Residual Current: 30mA
  • Number Of Poles: 2
  • Leakage Current Type: A
  • Rated Voltage: 230V, Rated Insulation Voltage: 500V
  • Rated Impulse-Withstand Voltage (Uimp): 4kV
  • Short-Circuit Breaking Capacity (Icw): 6kA
  • Surge Current Capacity: 0.25kA
  • Pollution Degree: 2
  • Degree Of Protection: IP20
  • Mounting: DIN Rail, Width: 2 Modular Spacings
  • Terminal Capacity: Up To 25mm² Rigid, 16mm² Flexible
  • Operating Temperature: From -25°C
  • Compliant With BS EN 61008 & IEC1008

If you need some help, would like to take advantage of our Price Promise or have a large order to place, give our team of professionals a call on 0203 994 5470, drop us an email at sales@electricpoint.com or use our Contact Form.

Model Number: CDA240U
Brand: Hager
Manufacturer: Hager Ltd
Product Type: Residual Current Circuit Breaker (RCCB)
Rated Current: 40A
Rated Residual Current: 30mA
Leakage Current Type: A
Number Of Poles: 2
Rated Voltage: 230V
Rated Insulation Voltage (Ui): 500V
Rated Impulse-Withstand Voltage (Uimp): 4kV
Frequency: 50Hz
Short-Circuit Breaking Capacity (Icw): 6kA
Surge Current Capacity: 0.25kA
Pollution Degree: 2
Degree Of Protection (IP Rating): IP20
Mounting Method: DIN Rail
Width: 2 Modular Spacings
Recess Depth: 70mm
Connectable Conductor Cross Section (Solid-Core): 1mm²
Connectable Conductor Cross Section (Multi-Wired): 1mm²
Ambient Operating Temperature: From -25°C
Compliance: BS EN 61008, IEC1008
Order Unit: Each

Recommended Products